Convert QuarkXPress and PageMaker documents.Selecting a region changes the language and/or content on. If serialization and activation is successful, the following message displays:.Mac OS: adobe_prtk -tool=Type1Exception -accept -serial= -responsecode= -leid=InDesignServer-CS7-Mac-GM.Windows: adobe_prtk -tool=Type1Exception -accept -serial= -responsecode= -leid=InDesignServer-CS7-Win-GM.Return to the primary computer, and in the terminal/console window enter:.Enter the Request Code generated in step 1.On a device connected to the internet, go to and click Generate a Response Code.In a terminal or console window enter: adobe_prtk -tool=Type1Exception -generate -serial=.Enter the response code to serialize and activate the software Generate a request code, and then submit it to receive a response code. You'll need access to an internet connected device. If your computer is offline, you can serialize and activate the software using the following procedure. To find out how to install additional fonts, visit the installation page. You can re-install the older fonts by deleting the new font files from the default system font directory, and moving the old files back into that directory. This new directory will also contain a file named "Read Me.html" which lists the saved fonts, and the version numbers of the new and old font files. Windows: :\Program Files\Common Files\Adobe\SavedFonts\current Mac: /Library/Application Support/Adobe/SavedFonts/current The older fonts will be saved in the new directory: If the installer finds older versions of these fonts in the default system font directory, it will uninstall the older versions, and save them to a new directory. Many of these fonts are newer versions of fonts installed by InDesign CS6 Server. The InDesign CC Server installer installs fonts into a default system font directory. Therefore, this time represents the maximum time for which a client will have to wait. If a session is initiated before the maximum wait time at the server end, the call will be returned to the client. ‘-maxwaitss’ or ‘/maxwaitss’ (in seconds): It specifies the time for which a client is willing to wait for a session to begin.Also, for non-blocking session support, if a session could not be initiated, the client would receive an appropriate error message. If this argument is not provided, the server will continue to work as per the older CS6 implementation. ‘-noblockss’ or ‘/noblockss’: if the argument is provided, the BeginSession request will be non-blocking in nature.Also, the client can specify maximum time limit for which it is willing to get blocked.įor session support configuration, you can provide the following two (optional) command line arguments at the time of server launch: Now in InDesign CC Server, the client can dynamically communicate to the server whether the client wants to get blocked or not. Once a thread is returned to the pool by some module in the application, the new thread is picked and a session is initiated. The client remains blocked until a session is initiated and this could be a problem for some clients depending on their workflow. In InDesign CS6 Server, when a client requests server to begin a new session, the session gets blocked if the server currently does not have a free worker thread in the thread-pool.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |